TY - JOUR
T1 - Computed tomography system for total knee replacement planning and comparison with plain radiography measured by an orthopedic surgeon
AU - Huang, Yu Jui
AU - Huang, Yi Cheng
AU - Wang, Siang Cyun
AU - Ku, Ming Chou
PY - 2019/1/1
Y1 - 2019/1/1
N2 - In this study, a new CT measurement system was developed for preoperation evaluation of total knee replacement (TKR). To validate the developed imaging processing systems, TKR patients with and without a bowed lower limb were recruited. All patients underwent plain radiographs and CT scan before a TKR procedure. The precision and effectiveness of two measurements validated by an orthopedic surgeon and evaluated using the developed 3D computed tomography image system were compared. In vivo statistics data, particularly for Taiwanese patients, showed no difference between bowed lower limb and normal lower limb groups. The results of this study did not reveal a significant difference between the 3D-reconstructed CT images and 2D plain radiographs. However, the proposed 3D-reconstructed CT image measurement system demonstrated consistent measurements for TKR patients and for the bowed lower limb group in preoperative evaluation. The implemented system could be used in conjunction with the current 2D radiograph approach. The proposed system assist surgeons and patients when discussing operations and clinical approaches. Clinical results validated the system.
AB - In this study, a new CT measurement system was developed for preoperation evaluation of total knee replacement (TKR). To validate the developed imaging processing systems, TKR patients with and without a bowed lower limb were recruited. All patients underwent plain radiographs and CT scan before a TKR procedure. The precision and effectiveness of two measurements validated by an orthopedic surgeon and evaluated using the developed 3D computed tomography image system were compared. In vivo statistics data, particularly for Taiwanese patients, showed no difference between bowed lower limb and normal lower limb groups. The results of this study did not reveal a significant difference between the 3D-reconstructed CT images and 2D plain radiographs. However, the proposed 3D-reconstructed CT image measurement system demonstrated consistent measurements for TKR patients and for the bowed lower limb group in preoperative evaluation. The implemented system could be used in conjunction with the current 2D radiograph approach. The proposed system assist surgeons and patients when discussing operations and clinical approaches. Clinical results validated the system.
UR - http://www.scopus.com/inward/record.url?scp=85075536618&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85075536618&partnerID=8YFLogxK
U2 - 10.2352/J.ImagingSci.Technol.2019.63.5.050503
DO - 10.2352/J.ImagingSci.Technol.2019.63.5.050503
M3 - Article
AN - SCOPUS:85075536618
VL - 63
JO - Journal of Imaging Science and Technology
JF - Journal of Imaging Science and Technology
SN - 1062-3701
IS - 5
M1 - 050503
ER -