The transformer saturation and hysteresis characteristics are important to power systems under transient operations. Conventional methods to determine these characteristics required field test data and several supporting analyses. Due to complicated corelated factors, field tests for such purposes are difficult. Based on a theoretical approach, the transformer saturation and hysteresis characteristics have certain relations with the rms voltage/current relation curve and the current flow through the equivalent core resistor. This paper presents simplified analytical expression in polynomial form to determine the transformer saturation and hysteresis characteristics without field test data. Higher order approximations are simulated for comparison with various capacity transformers. The results are compared with experiments and simulations and show very good agreement. It is possible to determine accurate transformer saturation and hysteresis characteristics with this simplified procedure.

原文English
頁(從 - 到)2706-2712
頁數7
期刊IEEE Transactions on Magnetics
25
發行號3
DOIs
出版狀態Published - 1989 五月

指紋

Hysteresis loops
Hysteresis
Resistors
Polynomials
Electric potential
Experiments

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Electrical and Electronic Engineering

引用此文

Lin, Chin E. ; Wei, Jong Bi ; Huang, Ching Lien ; Huang, Chi Jen. / A New Model for Transformer Saturation Characteristics by Including Hysteresis Loops. 於: IEEE Transactions on Magnetics. 1989 ; 卷 25, 編號 3. 頁 2706-2712.
@article{471a524d644d43ef9ec3ba7c4f65c026,
title = "A New Model for Transformer Saturation Characteristics by Including Hysteresis Loops",
abstract = "The transformer saturation and hysteresis characteristics are important to power systems under transient operations. Conventional methods to determine these characteristics required field test data and several supporting analyses. Due to complicated corelated factors, field tests for such purposes are difficult. Based on a theoretical approach, the transformer saturation and hysteresis characteristics have certain relations with the rms voltage/current relation curve and the current flow through the equivalent core resistor. This paper presents simplified analytical expression in polynomial form to determine the transformer saturation and hysteresis characteristics without field test data. Higher order approximations are simulated for comparison with various capacity transformers. The results are compared with experiments and simulations and show very good agreement. It is possible to determine accurate transformer saturation and hysteresis characteristics with this simplified procedure.",
author = "Lin, {Chin E.} and Wei, {Jong Bi} and Huang, {Ching Lien} and Huang, {Chi Jen}",
year = "1989",
month = "5",
doi = "10.1109/20.24512",
language = "English",
volume = "25",
pages = "2706--2712",
journal = "IEEE Transactions on Magnetics",
issn = "0018-9464",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "3",

}

A New Model for Transformer Saturation Characteristics by Including Hysteresis Loops. / Lin, Chin E.; Wei, Jong Bi; Huang, Ching Lien; Huang, Chi Jen.

於: IEEE Transactions on Magnetics, 卷 25, 編號 3, 05.1989, p. 2706-2712.

研究成果: Article

TY - JOUR

T1 - A New Model for Transformer Saturation Characteristics by Including Hysteresis Loops

AU - Lin, Chin E.

AU - Wei, Jong Bi

AU - Huang, Ching Lien

AU - Huang, Chi Jen

PY - 1989/5

Y1 - 1989/5

N2 - The transformer saturation and hysteresis characteristics are important to power systems under transient operations. Conventional methods to determine these characteristics required field test data and several supporting analyses. Due to complicated corelated factors, field tests for such purposes are difficult. Based on a theoretical approach, the transformer saturation and hysteresis characteristics have certain relations with the rms voltage/current relation curve and the current flow through the equivalent core resistor. This paper presents simplified analytical expression in polynomial form to determine the transformer saturation and hysteresis characteristics without field test data. Higher order approximations are simulated for comparison with various capacity transformers. The results are compared with experiments and simulations and show very good agreement. It is possible to determine accurate transformer saturation and hysteresis characteristics with this simplified procedure.

AB - The transformer saturation and hysteresis characteristics are important to power systems under transient operations. Conventional methods to determine these characteristics required field test data and several supporting analyses. Due to complicated corelated factors, field tests for such purposes are difficult. Based on a theoretical approach, the transformer saturation and hysteresis characteristics have certain relations with the rms voltage/current relation curve and the current flow through the equivalent core resistor. This paper presents simplified analytical expression in polynomial form to determine the transformer saturation and hysteresis characteristics without field test data. Higher order approximations are simulated for comparison with various capacity transformers. The results are compared with experiments and simulations and show very good agreement. It is possible to determine accurate transformer saturation and hysteresis characteristics with this simplified procedure.

UR - http://www.scopus.com/inward/record.url?scp=0024663350&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024663350&partnerID=8YFLogxK

U2 - 10.1109/20.24512

DO - 10.1109/20.24512

M3 - Article

AN - SCOPUS:0024663350

VL - 25

SP - 2706

EP - 2712

JO - IEEE Transactions on Magnetics

JF - IEEE Transactions on Magnetics

SN - 0018-9464

IS - 3

ER -