Abstract
Conventionally the Hydro mechanical driver is used to regulate the variable speed of aircraft engine to provide approximately constant speed for aircraft generator system. DC Link Variable Speed Constant Frequency (VSCF) electrical power generator system is the advanced system available today. Generator VSCF (IGVSCF) system presented in this paper can increase efficiency and reliability and further reduce the maintenance man power per flight hour. The performances of IGVSCF system have been simulated by the computer program and the experimental operation has been done by a prototype IGVSCF system. These simulated results and experimental tests prove that the IGVSCF system is superior to DC Link VSCF and Hydro mechanical driver.
Original language | English |
---|---|
Pages | 148-155 |
Number of pages | 8 |
Publication status | Published - 1995 Dec 1 |
Event | Proceedings of the 1995 International IEEE/IAS Conference on Industrial Automation and Control: Emerging Technologies - Taipei, Taiwan Duration: 1995 May 22 → 1995 May 27 |
Other
Other | Proceedings of the 1995 International IEEE/IAS Conference on Industrial Automation and Control: Emerging Technologies |
---|---|
City | Taipei, Taiwan |
Period | 95-05-22 → 95-05-27 |
All Science Journal Classification (ASJC) codes
- Engineering(all)