Prototype induction generator VSCF system for aircraft

Ying Shing Shiao, Chin E. Lin

Research output: Contribution to conferencePaper

4 Citations (Scopus)

Abstract

Conventionally the Hydro mechanical driver is used to regulate the variable speed of aircraft engine to provide approximately constant speed for aircraft generator system. DC Link Variable Speed Constant Frequency (VSCF) electrical power generator system is the advanced system available today. Generator VSCF (IGVSCF) system presented in this paper can increase efficiency and reliability and further reduce the maintenance man power per flight hour. The performances of IGVSCF system have been simulated by the computer program and the experimental operation has been done by a prototype IGVSCF system. These simulated results and experimental tests prove that the IGVSCF system is superior to DC Link VSCF and Hydro mechanical driver.

Original languageEnglish
Pages148-155
Number of pages8
Publication statusPublished - 1995 Dec 1
EventProceedings of the 1995 International IEEE/IAS Conference on Industrial Automation and Control: Emerging Technologies - Taipei, Taiwan
Duration: 1995 May 221995 May 27

Other

OtherProceedings of the 1995 International IEEE/IAS Conference on Industrial Automation and Control: Emerging Technologies
CityTaipei, Taiwan
Period95-05-2295-05-27

Fingerprint

Asynchronous generators
Aircraft
Aircraft engines
Computer program listings

All Science Journal Classification (ASJC) codes

  • Engineering(all)

Cite this

Shiao, Y. S., & Lin, C. E. (1995). Prototype induction generator VSCF system for aircraft. 148-155. Paper presented at Proceedings of the 1995 International IEEE/IAS Conference on Industrial Automation and Control: Emerging Technologies, Taipei, Taiwan, .
Shiao, Ying Shing ; Lin, Chin E. / Prototype induction generator VSCF system for aircraft. Paper presented at Proceedings of the 1995 International IEEE/IAS Conference on Industrial Automation and Control: Emerging Technologies, Taipei, Taiwan, .8 p.
@conference{2eff2e9facf14ac7a17bf9083438659b,
title = "Prototype induction generator VSCF system for aircraft",
abstract = "Conventionally the Hydro mechanical driver is used to regulate the variable speed of aircraft engine to provide approximately constant speed for aircraft generator system. DC Link Variable Speed Constant Frequency (VSCF) electrical power generator system is the advanced system available today. Generator VSCF (IGVSCF) system presented in this paper can increase efficiency and reliability and further reduce the maintenance man power per flight hour. The performances of IGVSCF system have been simulated by the computer program and the experimental operation has been done by a prototype IGVSCF system. These simulated results and experimental tests prove that the IGVSCF system is superior to DC Link VSCF and Hydro mechanical driver.",
author = "Shiao, {Ying Shing} and Lin, {Chin E.}",
year = "1995",
month = "12",
day = "1",
language = "English",
pages = "148--155",
note = "Proceedings of the 1995 International IEEE/IAS Conference on Industrial Automation and Control: Emerging Technologies ; Conference date: 22-05-1995 Through 27-05-1995",

}

Shiao, YS & Lin, CE 1995, 'Prototype induction generator VSCF system for aircraft' Paper presented at Proceedings of the 1995 International IEEE/IAS Conference on Industrial Automation and Control: Emerging Technologies, Taipei, Taiwan, 95-05-22 - 95-05-27, pp. 148-155.

Prototype induction generator VSCF system for aircraft. / Shiao, Ying Shing; Lin, Chin E.

1995. 148-155 Paper presented at Proceedings of the 1995 International IEEE/IAS Conference on Industrial Automation and Control: Emerging Technologies, Taipei, Taiwan, .

Research output: Contribution to conferencePaper

TY - CONF

T1 - Prototype induction generator VSCF system for aircraft

AU - Shiao, Ying Shing

AU - Lin, Chin E.

PY - 1995/12/1

Y1 - 1995/12/1

N2 - Conventionally the Hydro mechanical driver is used to regulate the variable speed of aircraft engine to provide approximately constant speed for aircraft generator system. DC Link Variable Speed Constant Frequency (VSCF) electrical power generator system is the advanced system available today. Generator VSCF (IGVSCF) system presented in this paper can increase efficiency and reliability and further reduce the maintenance man power per flight hour. The performances of IGVSCF system have been simulated by the computer program and the experimental operation has been done by a prototype IGVSCF system. These simulated results and experimental tests prove that the IGVSCF system is superior to DC Link VSCF and Hydro mechanical driver.

AB - Conventionally the Hydro mechanical driver is used to regulate the variable speed of aircraft engine to provide approximately constant speed for aircraft generator system. DC Link Variable Speed Constant Frequency (VSCF) electrical power generator system is the advanced system available today. Generator VSCF (IGVSCF) system presented in this paper can increase efficiency and reliability and further reduce the maintenance man power per flight hour. The performances of IGVSCF system have been simulated by the computer program and the experimental operation has been done by a prototype IGVSCF system. These simulated results and experimental tests prove that the IGVSCF system is superior to DC Link VSCF and Hydro mechanical driver.

UR - http://www.scopus.com/inward/record.url?scp=0029476902&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0029476902&partnerID=8YFLogxK

M3 - Paper

AN - SCOPUS:0029476902

SP - 148

EP - 155

ER -

Shiao YS, Lin CE. Prototype induction generator VSCF system for aircraft. 1995. Paper presented at Proceedings of the 1995 International IEEE/IAS Conference on Industrial Automation and Control: Emerging Technologies, Taipei, Taiwan, .