Evaluation of the dialysis time required for carbon dots by HPLC and the properties of carbon dots after HPLC fractionation

Chou Yen Chen, Yi Hua Tsai, Chih Wei Chang

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

In this study, we have employed carbon dots (C-dots) derived from citric acid as a model system to demonstrate the use of high performance liquid chromatography (HPLC) in evaluating the dialysis time required for carbon dots. The time evolution of the HPLC chromatograms indicates that about ∼120 hours are required to completely remove the small molecular byproducts of C-dots from the solution. Our study clearly demonstrated that in many C-dot-related studies, the C-dots were dialyzed inadequately. Furthermore, HPLC analysis shows that at least three C-dots coexist in the dialyzed solution. These C-dots exhibit similar optical properties and size distributions, but they have different surface functional groups, Hg2+ ion sensitivities and photoreduction capabilities. These findings suggest that more attention should be paid to the purification of C-dots, and it is important to establish a standard protocol to purify and characterize C-dots.

Original languageEnglish
Pages (from-to)6153-6159
Number of pages7
JournalNew Journal of Chemistry
Volume43
Issue number16
DOIs
Publication statusPublished - 2019 Jan 1

Fingerprint

Dialysis
High performance liquid chromatography
Fractionation
Carbon
Citric acid
Citric Acid
Functional groups
Purification
Byproducts
Optical properties
Ions

All Science Journal Classification (ASJC) codes

  • Catalysis
  • Chemistry(all)
  • Materials Chemistry

Cite this

@article{ad0829c84b6f4a2bbc1a7ddfe096f891,
title = "Evaluation of the dialysis time required for carbon dots by HPLC and the properties of carbon dots after HPLC fractionation",
abstract = "In this study, we have employed carbon dots (C-dots) derived from citric acid as a model system to demonstrate the use of high performance liquid chromatography (HPLC) in evaluating the dialysis time required for carbon dots. The time evolution of the HPLC chromatograms indicates that about ∼120 hours are required to completely remove the small molecular byproducts of C-dots from the solution. Our study clearly demonstrated that in many C-dot-related studies, the C-dots were dialyzed inadequately. Furthermore, HPLC analysis shows that at least three C-dots coexist in the dialyzed solution. These C-dots exhibit similar optical properties and size distributions, but they have different surface functional groups, Hg2+ ion sensitivities and photoreduction capabilities. These findings suggest that more attention should be paid to the purification of C-dots, and it is important to establish a standard protocol to purify and characterize C-dots.",
author = "Chen, {Chou Yen} and Tsai, {Yi Hua} and Chang, {Chih Wei}",
year = "2019",
month = "1",
day = "1",
doi = "10.1039/c9nj00434c",
language = "English",
volume = "43",
pages = "6153--6159",
journal = "New Journal of Chemistry",
issn = "1144-0546",
publisher = "Royal Society of Chemistry",
number = "16",

}

Evaluation of the dialysis time required for carbon dots by HPLC and the properties of carbon dots after HPLC fractionation. / Chen, Chou Yen; Tsai, Yi Hua; Chang, Chih Wei.

In: New Journal of Chemistry, Vol. 43, No. 16, 01.01.2019, p. 6153-6159.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Evaluation of the dialysis time required for carbon dots by HPLC and the properties of carbon dots after HPLC fractionation

AU - Chen, Chou Yen

AU - Tsai, Yi Hua

AU - Chang, Chih Wei

PY - 2019/1/1

Y1 - 2019/1/1

N2 - In this study, we have employed carbon dots (C-dots) derived from citric acid as a model system to demonstrate the use of high performance liquid chromatography (HPLC) in evaluating the dialysis time required for carbon dots. The time evolution of the HPLC chromatograms indicates that about ∼120 hours are required to completely remove the small molecular byproducts of C-dots from the solution. Our study clearly demonstrated that in many C-dot-related studies, the C-dots were dialyzed inadequately. Furthermore, HPLC analysis shows that at least three C-dots coexist in the dialyzed solution. These C-dots exhibit similar optical properties and size distributions, but they have different surface functional groups, Hg2+ ion sensitivities and photoreduction capabilities. These findings suggest that more attention should be paid to the purification of C-dots, and it is important to establish a standard protocol to purify and characterize C-dots.

AB - In this study, we have employed carbon dots (C-dots) derived from citric acid as a model system to demonstrate the use of high performance liquid chromatography (HPLC) in evaluating the dialysis time required for carbon dots. The time evolution of the HPLC chromatograms indicates that about ∼120 hours are required to completely remove the small molecular byproducts of C-dots from the solution. Our study clearly demonstrated that in many C-dot-related studies, the C-dots were dialyzed inadequately. Furthermore, HPLC analysis shows that at least three C-dots coexist in the dialyzed solution. These C-dots exhibit similar optical properties and size distributions, but they have different surface functional groups, Hg2+ ion sensitivities and photoreduction capabilities. These findings suggest that more attention should be paid to the purification of C-dots, and it is important to establish a standard protocol to purify and characterize C-dots.

UR - http://www.scopus.com/inward/record.url?scp=85064411587&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85064411587&partnerID=8YFLogxK

U2 - 10.1039/c9nj00434c

DO - 10.1039/c9nj00434c

M3 - Article

AN - SCOPUS:85064411587

VL - 43

SP - 6153

EP - 6159

JO - New Journal of Chemistry

JF - New Journal of Chemistry

SN - 1144-0546

IS - 16

ER -