Based on a theoretical approach, the transformer saturation characteristic has certain relation with the rms voltage/current relation curve. A simplified analytical expression is presented for determining the transformer saturation characteristic without field test data. Higher-order approximations are simulated for comparisons with various transformer capacities. For various purposes of the transformer saturation characteristics, the proposed method has the capability to revise the results for different approaches. It is capable of determining accurate transformer saturation characteristics, with the aid of simplified procedures.

Original languageEnglish
Title of host publicationUnknown Host Publication Title
PublisherIEEE
Pages605-609
Number of pages5
Publication statusPublished - 1987 Dec 1

Fingerprint

Electric potential

All Science Journal Classification (ASJC) codes

  • Engineering(all)

Cite this

Lin, C. E., Wei, J-B., Huang, C. L., & Huang, C. J. (1987). DIRECT APPROXIMATION FOR TRANSFORMER SATURATION CHARACTERISTIC WITH IMPROVED ANALYTICAL METHOD. In Unknown Host Publication Title (pp. 605-609). IEEE.
Lin, C. E. ; Wei, Jong-Bi ; Huang, C. L. ; Huang, C. J. / DIRECT APPROXIMATION FOR TRANSFORMER SATURATION CHARACTERISTIC WITH IMPROVED ANALYTICAL METHOD. Unknown Host Publication Title. IEEE, 1987. pp. 605-609
@inproceedings{3a4d96f2031c4bebb37ba60ff0407aaa,
title = "DIRECT APPROXIMATION FOR TRANSFORMER SATURATION CHARACTERISTIC WITH IMPROVED ANALYTICAL METHOD.",
abstract = "Based on a theoretical approach, the transformer saturation characteristic has certain relation with the rms voltage/current relation curve. A simplified analytical expression is presented for determining the transformer saturation characteristic without field test data. Higher-order approximations are simulated for comparisons with various transformer capacities. For various purposes of the transformer saturation characteristics, the proposed method has the capability to revise the results for different approaches. It is capable of determining accurate transformer saturation characteristics, with the aid of simplified procedures.",
author = "Lin, {C. E.} and Jong-Bi Wei and Huang, {C. L.} and Huang, {C. J.}",
year = "1987",
month = "12",
day = "1",
language = "English",
pages = "605--609",
booktitle = "Unknown Host Publication Title",
publisher = "IEEE",

}

Lin, CE, Wei, J-B, Huang, CL & Huang, CJ 1987, DIRECT APPROXIMATION FOR TRANSFORMER SATURATION CHARACTERISTIC WITH IMPROVED ANALYTICAL METHOD. in Unknown Host Publication Title. IEEE, pp. 605-609.

DIRECT APPROXIMATION FOR TRANSFORMER SATURATION CHARACTERISTIC WITH IMPROVED ANALYTICAL METHOD. / Lin, C. E.; Wei, Jong-Bi; Huang, C. L.; Huang, C. J.

Unknown Host Publication Title. IEEE, 1987. p. 605-609.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

TY - GEN

T1 - DIRECT APPROXIMATION FOR TRANSFORMER SATURATION CHARACTERISTIC WITH IMPROVED ANALYTICAL METHOD.

AU - Lin, C. E.

AU - Wei, Jong-Bi

AU - Huang, C. L.

AU - Huang, C. J.

PY - 1987/12/1

Y1 - 1987/12/1

N2 - Based on a theoretical approach, the transformer saturation characteristic has certain relation with the rms voltage/current relation curve. A simplified analytical expression is presented for determining the transformer saturation characteristic without field test data. Higher-order approximations are simulated for comparisons with various transformer capacities. For various purposes of the transformer saturation characteristics, the proposed method has the capability to revise the results for different approaches. It is capable of determining accurate transformer saturation characteristics, with the aid of simplified procedures.

AB - Based on a theoretical approach, the transformer saturation characteristic has certain relation with the rms voltage/current relation curve. A simplified analytical expression is presented for determining the transformer saturation characteristic without field test data. Higher-order approximations are simulated for comparisons with various transformer capacities. For various purposes of the transformer saturation characteristics, the proposed method has the capability to revise the results for different approaches. It is capable of determining accurate transformer saturation characteristics, with the aid of simplified procedures.

UR - http://www.scopus.com/inward/record.url?scp=0023600503&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0023600503&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:0023600503

SP - 605

EP - 609

BT - Unknown Host Publication Title

PB - IEEE

ER -

Lin CE, Wei J-B, Huang CL, Huang CJ. DIRECT APPROXIMATION FOR TRANSFORMER SATURATION CHARACTERISTIC WITH IMPROVED ANALYTICAL METHOD. In Unknown Host Publication Title. IEEE. 1987. p. 605-609