Decomposition of the IEC flickermeter weighting curves

Chau-Shing Wang, Michael J. Devaney, Shih Wei Yang

Research output: Chapter in Book/Report/Conference proceedingConference contribution

8 Citations (Scopus)

Abstract

Most people have experience the sensation of varying light intensity from lamps as other loads connected to the same mains circuit draw fluctuating current. This perceptible variation in light is called flicker. To measure flicker, The IEC has defined two weighting curves for flicker frequency on 230V/50Hz and 120V/60Hz systems respectively. In this paper we explore the relationship between these two curves and propose a light flicker weighting curve which is independent of the light bulb types as well as the supplying source system. This novel curve can be exploited to weight the light flicker spectrum for all kinds of lamps and then report the flicker severity index.

Original languageEnglish
Title of host publicationProceedings of the 21st IEEE Instrumentation and Measurement Technology Conference, IMTC/04
EditorsS. Demidenko, R. Ottoboni, D. Petri, V. Piuri, D.C.T. Weng
Pages1378-1382
Number of pages5
DOIs
Publication statusPublished - 2004 Oct 8
EventProceedings of the 21st IEEE Instrumentation and Measurement Technology Conference, IMTC/04 - Como, Italy
Duration: 2004 May 182004 May 20

Publication series

NameConference Record - IEEE Instrumentation and Measurement Technology Conference
Volume2
ISSN (Print)1091-5281

Other

OtherProceedings of the 21st IEEE Instrumentation and Measurement Technology Conference, IMTC/04
CountryItaly
CityComo
Period04-05-1804-05-20

All Science Journal Classification (ASJC) codes

  • Electrical and Electronic Engineering

Fingerprint Dive into the research topics of 'Decomposition of the IEC flickermeter weighting curves'. Together they form a unique fingerprint.